If the airman passes the operational color vision perception test(s), then he/she will be issued a Letter of Evidence (LOE). Specialized Operational Medical Tests for Applicants Who Do Not Meet the Standard.Īpplicants who fail the color vision screening test as listed, but desire an airman medical certificate without the color vision limitation, may be given, upon request, an opportunity to take and pass additional operational color perception tests. See bold paragraph in the introduction of this section (above).ĭ. The color vision screening tests above (Section A) are not to be used for the purpose of removing color vision limits/restrictions from medical certificates of airmen who have failed the Specialized Operational Medical Tests below (Section D). NOT VALID FOR NIGHT FLYING OR BY COLOR SIGNAL CONTROLĬ. If an applicant fails to meet the color vision standard as interpreted above but is otherwise qualified, the Examiner must issue a medical certificate bearing the limitation: Approved Computerized Tests - for scoring criteria, see information table.Plates 1-4 are for demonstration only plates 5-10 are screening plates and plates 11-24 are diagnostic plates. Richmond-HRR, 4th edition: two or more errors on plates 5-24.Titmus Vision Tester, Titmus i400, OPTEC 2000 Vision Tester, Keystone Orthoscope, or Keystone View Telebinocular: any errors in the six plates.OPTEC 900 Vision tester and Farnsworth Lantern test: an average of more than one error per series of nine color pairs in series 2 and 3. ![]() Richmond (1983 edition) pseudoisochromatic plates: seven or more errors on plates 1-15.Ishihara pseudoisochromatic plates: Concise 14-plate edition: six or more errors on plates 1-11 the 24-plate edition: seven or more errors on plates 1-15 the 38-plate edition: nine or more errors on plates 1-21. ![]() Dvorine pseudoisochromatic plates (second edition, 15 plates): seven or more errors on plates 1-15.Because the first 4 plates in the test book are for demonstration only, test plate 7 is actually the eleventh plate in the book. AOC-HRR (second edition): Any error in test plates 7-11.AOC (1965 edition) pseudoisochromatic plates: seven or more errors on plates 1-15.That pathway is no longer an option to the airman, and no new result will be considered.Īn applicant does not meet the color vision standard if testing reveals: Color Vision as an attempt to remove any color vision limits or restrictions on their airman medical certificate. Inform the applicant that if he/she takes and fails any component of the Specialized Operational Medical Tests ( PDF) in Section D, then he/she will not be permitted to take any of the remaining listed office-based color vision tests in Examination Techniques, Item 52. Color Vision Examination Equipment and Techniques before requesting the Specialized Operational Medical Tests in Section D below. If an applicant fails any of these tests, inform the applicant of the option of taking any of the other acceptable color vision tests listed in Item 52. The following criteria apply to PILOTS ONLY:Īn applicant meets the color vision standard if he/she passes any of the color vision tests listed in Examination Techniques, Item 52. TESTS APPROVED FOR AIRMEN ARE NOT ALL ACCEPTABLE FOR AIR TRAFFIC CONTROLLERS (FAA employee 2152 series and contract tower air traffic controllers).įOR ATCS INFORMATION, see the Acceptable Test Instruments for Color Vision Screening of ATCS ( PDF) chart or contact your RFS for any questions. Recreational Flyers & Modeler Community-Based Organizationsĭecision Considerations Aerospace Medical Dispositions.Critical Infrastructure & Public Venues.Certificated Remote Pilots including Commercial Operators. ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |